Dự án

Tổng quan

Hồ sơ

Task #468

Cập nhật bởi Tùng Nguyễn cách đây 10 tháng

Mô tả: disk SSD 480G làm OSD.7 bị chậm làm ảnh hưởng đến các VM S3 GW đang chạy nhưng không có log báo disk lỗi 
 ![](clipboard-202401301035-xdue8.png) 
 ![](clipboard-202401301035-g0kxj.png) 
 === 
 Thông tin disk chậm 
 ``` yaml 
 root@prox2-s3:~# udevadm info /dev/sdd 
 P: /devices/pci0000:00/0000:00:03.0/0000:04:00.0/host0/port-0:0/expander-0:0/port-0:0:3/end_device-0:0:3/target0:0:3/0:0:3:0/block/sdd 
 M: sdd 
 U: block 
 T: disk 
 D: b 8:48 
 N: sdd 
 L: 0 
 S: disk/by-path/pci-0000:04:00.0-sas-exp0x5001636001caa8ff-phy5-lun-0 
 S: disk/by-id/lvm-pv-uuid-1H1tCb-CIV0-2Z1Q-pvcf-qIEg-ie2c-eJAbOR 
 S: disk/by-diskseq/12 
 S: disk/by-id/ata-Netac_SSD_NT-480N6S_8EC60757160802226488 
 Q: 12 
 E: DEVPATH=/devices/pci0000:00/0000:00:03.0/0000:04:00.0/host0/port-0:0/expander-0:0/port-0:0:3/end_device-0:0:3/target0:0:3/0:0:3:0/block/sdd 
 E: DEVNAME=/dev/sdd 
 E: DEVTYPE=disk 
 E: DISKSEQ=12 
 E: MAJOR=8 
 E: MINOR=48 
 E: SUBSYSTEM=block 
 E: USEC_INITIALIZED=12223711 
 E: ID_ATA=1 
 E: ID_TYPE=disk 
 E: ID_BUS=ata 
 E: ID_MODEL=Netac_SSD_NT-480N6S 
 E: ID_MODEL_ENC=Netac\x20SSD\x20NT-480N6S\x20\x20\x20\x20\x20\x20\x20\x20\x20\x20\x20\x20\x20\x20\x20\x20\x20\x20\x20\x20\x20 
 E: ID_REVISION=SAFM01.5 
 E: ID_SERIAL=Netac_SSD_NT-480N6S_8EC60757160802226488 
 E: ID_SERIAL_SHORT=8EC60757160802226488 
 E: ID_ATA_WRITE_CACHE=1 
 E: ID_ATA_WRITE_CACHE_ENABLED=1 
 E: ID_ATA_FEATURE_SET_HPA=1 
 E: ID_ATA_FEATURE_SET_HPA_ENABLED=1 
 E: ID_ATA_FEATURE_SET_PM=1 
 E: ID_ATA_FEATURE_SET_PM_ENABLED=1 
 E: ID_ATA_FEATURE_SET_SECURITY=1 
 E: ID_ATA_FEATURE_SET_SECURITY_ENABLED=0 
 E: ID_ATA_FEATURE_SET_SECURITY_ERASE_UNIT_MIN=2 
 E: ID_ATA_FEATURE_SET_SECURITY_ENHANCED_ERASE_UNIT_MIN=2 
 E: ID_ATA_FEATURE_SET_SMART=1 
 E: ID_ATA_FEATURE_SET_SMART_ENABLED=1 
 E: ID_ATA_FEATURE_SET_APM=1 
 E: ID_ATA_FEATURE_SET_APM_ENABLED=1 
 E: ID_ATA_FEATURE_SET_APM_CURRENT_VALUE=254 
 E: ID_ATA_DOWNLOAD_MICROCODE=1 
 E: ID_ATA_SATA=1 
 E: ID_ATA_SATA_SIGNAL_RATE_GEN2=1 
 E: ID_ATA_SATA_SIGNAL_RATE_GEN1=1 
 E: ID_ATA_ROTATION_RATE_RPM=0 
 E: ID_PATH=pci-0000:04:00.0-sas-exp0x5001636001caa8ff-phy5-lun-0 
 E: ID_PATH_TAG=pci-0000_04_00_0-sas-exp0x5001636001caa8ff-phy5-lun-0 
 E: ID_FS_UUID=1H1tCb-CIV0-2Z1Q-pvcf-qIEg-ie2c-eJAbOR 
 E: ID_FS_UUID_ENC=1H1tCb-CIV0-2Z1Q-pvcf-qIEg-ie2c-eJAbOR 
 E: ID_FS_VERSION=LVM2 001 
 E: ID_FS_TYPE=LVM2_member 
 E: ID_FS_USAGE=raid 
 E: SYSTEMD_READY=1 
 E: DEVLINKS=/dev/disk/by-path/pci-0000:04:00.0-sas-exp0x5001636001caa8ff-phy5-lun-0 /dev/disk/by-id/lvm-pv-uuid-1H1tCb-CIV0-2Z1Q-pvcf-qIEg-ie2c-eJAbOR /dev/disk/by-diskseq/12 /dev/disk/by-id/ata-Netac_SSD_NT> 
 E: TAGS=:systemd: 
 E: CURRENT_TAGS=:systemd: 

 ``` 

 Xử lý: 
 1. Tạm thời maintenance cluster: noout,norebalance,nobackfill 
 Stop service osd.7 
 2.  
 - Chuẩn bị thêm disk SSD 400G để cắm thêm cho server 
 - Chuyển disk OSD.7 qua slot khác và theo dõi tiếp

Quay lại